Pt Temperature Transmitter DT 45200
- Measuring input for all Pt temperature sensors
more than 1200 standard ranges ready to use - Easy configurable via DIP switches
or via USB interface without auxiliary power supply - Switchable Service Functions
for an easy commissioning - 3-port isolation
Protection against erroneous measurements due to parasitic voltages or ground loops - Extremely slim design
6.2 mm slim housing for a simple and space saving DIN rail mounting - Optional In-Rail-Bus mounting rail connector
allows for fast and economical installation - Protective Separation acc. to EN 61140
Protects service personnel and downstream devices against impermissibly high voltage - 5 Years Warranty
Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
|
|
DT45200
초슬림형 Pt 온도센서 RTD 신호전송기 Pt Temperature Transmitter DT 45200
Pt 센서로 온도 측정, DIP 스위치 또는 USB를 통해 설정 가능
Pt 온도 트랜스미터 DT 45200은 산업 공정 신호를 측정하는데 사용됩니다. Pt 센서 신호를 절연된 표준 신호로 변환합니다.
The Pt Temperature Transmitter DT 45200 is used for measure industrial process signals. It converts Pt sensor signals to isolated standard signals.
|
센서입력 | RTD
Pt100
Pt200 Pt500
Pt1000 Pt2000
JPt50 JPt100
(2/3/4선식) | |
출력 | 0 ~ 20mA 4 ~ 20mA 0 ~ 10V 0 ~ 5V | |
측정범위 | -200 ~ +850°C | |
전원 | 24V DC
(전원
배선 Bus 단자 옵션) | |
특징 | 2
/ 3 / 4선식
다양한 Pt RTD 센서 입력 두께
6.2mm 초슬림형, UL 인증, 방폭
(Zone 2) 인증 DIP 스위치
또는 PC에서 입력/출력 설정
및 변경
|
- 모든 Pt 온도 센서에 대한 측정 입력
사용할 수
있는 1200 개 이상의 표준 범위
- DIP 스위치를 통해 손쉽게 설정 가능
또는 보조 전원 공급
없이 USB 인터페이스를 통해
- 전환 가능한 서비스 기능
쉬운 업무수행을 위해
- 3-Port 절연
부유전압(Stray
Voltage) 또는 접지루프(Ground
Loop)로 인한 잘못된 측정으로부터 보호
- 매우 슬림한 디자인
간단하고 공간 절약을
위한 6.2mm 슬림 하우징 DIN 레일 장착
- 옵션 In-Rail-Bus 마운팅 레일 커넥터
빠르고 경제적인 설치가 가능합니다.
- EN
61140 (KS
C IEC 61140) 규격에 따른 감전보호
허용되지 않는 고전압으로부터 서비스 요원 및 후속 장치를 보호
- 5년 보증
배송일로부터 5년 이내에 발생하는 결함은 무료로 수리
또는 교환해 드립니다.
|
RTD
온도 신호전송기(Pt Temperature Transmitter) DT45200은
산업 공정신호를 측정하는데 사용됩니다. Pt 센서신호를
절연된 표준신호로 변환합니다.
DIP
스위치를 통해 교정된 측정범위를 쉽게 설정할 수 있기
때문에 신호전송기는 유연한 사용에 적합합니다.
USB
프로그래밍 키트인 드라고세트(DRAGOset)를
사용하면 신호전송기를 설정하고 모든 데이터를 PC에 저장할
수 있습니다. 프로그래밍 모드에서는 추가 보조전원이 필요하지
않습니다.
전면
패널에서 전환할 수 있는 시운전 기능은 하부 신호경로
테스트 및 조정을 위한 출력 기준신호를 생성합니다.
보조전원은
연결단자 또는 옵션사양인 인레일버스(In-Rail-Bus)
커넥터를 통해 공급할 수 있습니다. 전원공급 및 센서
연결 상태가 전면의 LED로 표시됩니다.
The Pt Temperature Transmitter DT 45200 is used for measure industrial process signals. It converts Pt sensor signals to isolated standard signals.
Due to the easy setting of the calibrated measuring ranges via DIP switch the Transmitter is suitable for flexible use. With the USB Programming-Kit DRAGOset the Transmitter can be configured and all data can be stored by a PC. In mode of programming no additionally auxiliary power is required. The Commissioning Function, switchable on front panel, generates an output reference signal for testing and adjusting of the downstream signal path. The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. The status of power supply and sensor connection will be displayed by a LED on front.
Technical Data
Input
| Sensor | Pt100, Pt200, Pt500, Pt1000, Pt2000 acc. IEC 60751 JPt50, JPt100 (TK3916) acc. JIS C 1604 | | Measuring range | -200 bis +850 °C in calibrated steps of 25 °C, configurable via DIP switch or USB interface | | Measuring span min. | 25 K | | Measuring error | < 0.1 K + 0.05 % meas. val. | | Sensor connection | 4-wire, 3-wire, 2-wire | | Sensor current | 0.2 mA | | Cable resistance | < 100 Ohm per wire at 4-wire and 3-wire connection |
|
Output
| | Current | Voltage | | Output signal | 0 to 20mA, 4 to 20mA | 0 to 5V, 0 to 10V | | Load | ≤ 12 V (600 Ohm @ 20 mA) | ≤ 5 mA (2 kOhm @ 10 V) | | Residual ripple | < 10 mVrms | | transfer range | 0 to 102.5 % (3.8 to 20.5 mA at output 4 to 20 mA) | Transfer characteristic rising/falling | | Error signal | Sensor/wire break, error signal programmable |
General data
| Transmission error | < 0.1 % full scale | | Temperature coefficient1) | < 100 ppm/K | | Sampling rate | 4/s | | Response time T99 | 250 ms | | Test voltage | 3 kV AC, 50 Hz, 1 min | Input against output against power supply | Working voltage 2) (basic insulation) | 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 | | Protection against electric shock 2) | Protective Separation by reinforced insulation acc. to EN 61010-1 up to 300 V AC/DC for overvoltage category II and contamination class 2 between input and output and power supply. | | Ambient temperature | Operation Transport and storage | -25 °C to +70 °C -40 °C to +85 °C | (-13 to +158 °F) (-40 to +185 °F) | | Power supply | 24 V DC, voltage range 9.6 V to 31.2 V DC, approx. 0.8 W | | EMC 3) | EN 61326-1 | | Approvals | UL (USA/Canada): UL 61010, Class I, Div. 2 ATEX / IECEx: Zone 2 (nA) |
| Construction | 6.2 mm (0.244") housing, protection type: IP 20 mounting on 35 mm DIN rail acc. to EN 60715 | | Weight | Approx. 70 g |
|
Block
Diagram
|
Dimensions
|
| 
|

|
Terminal assignments
|
1 |
+ | Input Pt | |
2 |
+ | Input 3/4-wire | |
3 |
- | Input 4-wire | |
4 |
- | Input Pt | |
|
| | |
5 |
+ | Output | |
6 |
- | Output | |
|
| | |
7 |
+ | Power supply (connected to In-Rail-Bus) | |
8 |
- | Power supply (connected to In-Rail-Bus) |
|
2/3/4-wire
Pt Sensor Input Wiring

Connection Captive plus-minus clamp screws Wire cross-section max. 2.5 mm² / AWG 14 Stripped length 6 to 8 mm / 0.28 in Screw terminal torque 0.8 Nm / 7 lbf in Optional power connection via In-Rail-Bus (see accessories)
|
제품
주문 코드 Order Codes
| 품목 |
주문번호 |
초슬림형
Pt
온도센서 RTD 신호전송기 (트랜스미터) USB
인터페이스 또는 DIP 스위치를 이용하여
입력/출력신호
형식을 선택하여 설정
Pt
Temperature Transmitter, Programmable via USB and DIP switch 전원연결버스
(In-Rail-Bus): 부속품 참조
|
전원
Bus
단자 무 |
전원
Bus
단자 유 |
|
DT 45200 S |
DT 45200 B |
여기에
표기된 사양들은 예고 없이 변경될 수 있습니다! (Specifications
listed here are subject to change without notice!)

|