드라고 신호변환기      DRAGO Signal Converters

측정, 제어, 자동화를 위한 산업용 신호처리, DRAGO가 합니다.

페이지

Homepage

제품군

Product Line

제품소개

Products

신호변환기 선정 가이드

Selection Matrix

제품 전체 보기

Service Web Portals

내려받기

Downloads

제품 및 구입 문의

Contact

DH18

Loop-Powered (Passive) Isolator DH 18

 

  • 1- and 2-channel versions
    Economical separation for standard applications
  • Only 60 mm installation depth, 11.2 mm wide
    Can be installed in economical standard terminal boxes
  • Galvanic isolation across input and output
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • High reliability and long-term stability
    New APT technology for signal processing
  • Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage
  • No power supply required
    Saving costs since wiring is reduced and line influences are omitted
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

DH18 경제형 루프파워 (무전원) 신호 아이솔레이터
Loop-Powered (Passive) Isolator DH 18

0(4) ~ 20mA 산업용 표준 전류 신호의 분리 및 절연

입력 루프 전원 절연기 DH 18은 0(4) ~ 20mA 표준 신호의 전기적 절연에 사용됩니다.

The input loop-powered isolator DH 18 is used for the electrical isolation of 0(4) to 20 mA standard signals.

입력

0 ~ 20mA     4 ~ 20mA

출력

0 ~ 20mA     4 ~ 20mA

전원

무전원 (Input Loop-Powered)

특징

초저비용, 슬림/초소형 (60 x 60 x 11.2mm)
1채널 / 2채널 옵션

  • 1 및 2채널 버전
    표준 활용을 위한 경제적인 분리
  • 단지 60mm 설치 깊이, 폭 11.2mm
    경제적인 표준 단자함에 설치할 수 있습니다.
  • 입력 및 출력간의 갈바닉 절연
    부유
    전압(S
    tray Voltage) 또는 접지루프(Ground Loop)로 인한 잘못된 측정으로부터 보호
  • 높은 신뢰성과 장기 안정성
    최신 첨단
    신호 처리 기술
  • EN 61140 (KS C IEC 61140) 규격에 따른 감전보호
    허용되지 않는 고전압으로부터 서비스 요원 및 후속 장치를 보호합니다.
  • 전원 공급 장치가 필요하지 않습니다.
    배선이 줄어들고 선로 영향이 생략되므로 비용 절감
  • 5년 보증
    배송
    일로부터 5년 이내에 발생하는 결함은 무료로 수리 또는 교환해 드립니다.

입력 루프 전원 신호절연기(Input Loop-Powered Isolator) DH18은 0(4) ~ 20mA 표준신호의 전기적 절연에 사용됩니다.

DH18은 측정신호를 높은 정확도로 출력으로 전송하고 간섭전압(Interference Voltage)이 하위로 이어지는 것을 방지하고 효과적으로 간섭을 억제합니다. 하나 또는 두 개의 채널에 대해 폭 11.2mm의 슬림형 하우징은 DIN 레일에 상당한 공간을 확보합니다.

지능형 설계와 그에 따른 고도로 집적된 부품의 필수적인 방지기능은 측정신호의 왜곡 없이 매우 긴 수명과 신뢰성을 제공합니다.

허용되지 않는 고전압에 대한 유지보수 인원과 하위 설비를 보호하기 위해 DH18은 EN61140에 따라 방호분리(Protective Separation)를 제공합니다.

DH18은 보조전원이 입력신호에서 왜곡되지 않고 얻어지므로 추가 전원공급이 필요하지 않습니다. 이는 설치비용을 절감할 뿐만 아니라 신뢰성을 높입니다.

The input loop-powered isolator DH 18 is used for the electrical isolation of 0(4) to 20 mA standard signals.

The DH 18 transfers the measuring signal to the output with a high degree of accuracy and avoids interference voltage carry-over and suppressing interferences effectively. The slim housing with 11.2 mm wide for one or two channels saves significant space on the DIN-rail.

Intelligent design and their consequential avoidance of highly integrated components result in extremely long service lives and reliability without any falsification of the measurement signal.

To protect both maintenance personnel as well as downstream equipment against impermissibly high voltages, the DH 18 offers Protective Separation in according to EN 61140.

The DH 18 requires no additional power supply since the auxiliary power is obtained from the input signal without distorting it. This not only saves costs during installation, but also increases reliability.

활용 예:  입력 루프파워 (Input Loop-Powered) 0(4)~20mA 신호 아이솔레이터

DH18

 

Technical Data

Input

Input signal0(4) to 20 mA
Start-up current< 100 µA
Voltage drop< 3.0 V
Overload≤ 50 mA, 15 V

 

Output

Output signal0(4) to 20 mA
Load< 600 Ohm
Cut-off frequency -3 dB100 Hz
Response time T995 ms
Residual ripple< 10 mVrms

 

General Data

Transmission error< 0.1 % full scale
Load error< 0.05 % of measured value / 100 Ohm load
Temperature coefficient 1)< 0.004 %/K / 100 Ohm load
Test voltage2.5 kV, 50 Hz all circuits against one another
Working voltage 2)
(Basic Insulation)
Up to 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010–1
Protection against electrical shock 2)Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010–1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits.
Ambient temperatureOperation
Transport and storage
–20 °C to +60 °C    (–4 °F to +140 °F)
–35 °C to +85 °C    (–31 °F to +185 °F)
EMC 3)EN 61326 -1
Construction11.2 mm (0.44") housing, protection classt: IP 20
mounting on 35 mm DIN rail acc. to EN 60715
WeightApprox. 50 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  3. Minor deviations possible during interference

 

Block Diagram

Dimensions

DH18

DH18

Terminal assignments / Wire cross-section max. 2.5 mm²

Channel 1Channel 2

1

Input 1 +

3

Input 2 +

2

Input 1 -

4

Input 2 -

5

Output 1 +

7

Output 2 +

6

Output 1 -

8

Output 2 -

 

 

제품 주문 코드   Order Codes

품목

주문번호

루프 전원 신호절연기

Loop-powered isolator

1채널

DH 18 P–1

2채널

DH 18 P–2


여기에 표기된 사양들은 예고 없이 변경될 수 있습니다! (Specifications listed here are subject to change without notice!)
© Copyright 2004-2024 by DRAGO Automation GmbH

드라고 신호변환기 한국판매원 - 에이콤 (AKORM Corp.)