Temperature Measuring Contactor DG 3600
- Easy selection of operating mode
MIN/MAX alarm switch selectable, switch point and hysteresis adjustable on front panel - Relay with high power handling
or wearless optocoupler switching output - True 4-port separation
Protection against erroneous measurements due to parasitic voltages or ground loops - Switch state indicated by LED
Easy to adjust the set point and hysteresis - Protective Separation acc. to EN 50178
Protects service personnel and downstream devices against impermissibly high voltage - High reliability and long-term stability
No maintenance costs - Unlimited use with 24 V AC/DC power supply
Universally applicable for all measurement and industrial applications - 5 Years Warranty
Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
|
|
DG3600
Pt 온도 센서 RTD 신호 알람 릴레이 / 오픈콜렉터
스위치 출력 Temperature Alarm Unit DG 3600
경보 장치 DG 3600은 Pt 센서를 사용하여 한계값을 모니터링하고 온도 측정 활용에서 간단한 자동화 프로세스를 조정하는데 사용됩니다.
The Alarm Unit DG 3600 is used to monitor limit values and regulate simple automation processes in temperature measuring applications with Pt-Sensors.
입력 |
Pt100,
Pt200, Pt500, Pt1000 (전환가능)
|
출력릴레이 | 250V AC/DC, 6A |
전원 | 24V AC/DC |
특징 |
고출력
릴레이, 감전보호, 하우징 폭:
22.5mm
|
- 간편한 작동 모드 선택
전면 패널의 MIN/MAX 알람 스위치 선택 가능, 스위치 포인트 및 히스테리시스 조절 가능
- 고출력 릴레이가
있는 계전기
또는 무손실 포토커플러(Optocoupler) 스위칭 출력
- 완전한 4-port 분리
부유전압(Stray
Voltage) 또는 접지루프(Ground
Loop)로 인한 잘못된 측정으로부터 보호
- LED로 표시된 스위치 상태
설정 포인트 및 히스테리시스 조정이 쉽습니다.
- EN
50178
(전력설비에
사용되는 전자장비에 관한)
규격에 따른 감전보호
허용되지 않는 고전압으로부터 서비스 요원 및 후속 장치를 보호합니다.
- 높은 신뢰성과 장기 안정성
유지 보수 비용 없음
- 24V AC/DC 전원 공급 장치로 무제한 사용 가능
모든 측정 및 산업용 활용에 보편적으로 적용 가능
- 5년 보증
배송일로부터 5년 이내에 발생하는 결함은 무료로 수리
또는 교환해 드립니다.
|
신호경보기(Alarm
Unit) DG3600은 Pt 센서를 사용하여 온도측정 어플리케이션에서
한계값을 모니터링하고 간단한 자동화 프로세스를 조정하는데
사용됩니다.
높은
신뢰도와 방호분리(Protective Separation)는 결함이 없는
장치 작동에 기여하는 필수적인 특성입니다.
2개의
스위치 채널을 개별적으로 설정할 수 있습니다. 스위치
포인트(Switch Point)와 스위치 히스테리시스(Switch Hysteresis)는
경보기의 전면 패널에 위치한 자체 12회전 전위차계(12-turn
Potentiometer)를 사용하여 각각 조절할 수 있습니다. 스위치
상태는 노란색 LED로 표시됩니다.
효과방향
및 작동모드는 DIP 스위치 설정을 통해 전환할 수 있습니다.
두 스위치 출력은 MIN 또는 MAX 알람으로 설정할 수 있습니다.
릴레이 접점은 a접점(상시개로, N/O, Normally Open) 또는 b접점(상시폐로,
N/C,
Normally Closed)으로 높은 전력부하를 절환합니다.
DG3600은
방호분리 및 24V AC/DC 전원공급 장치를 통해 모든 계측,
산업용 어플리케이션 및 빌딩 자동화에 보편적으로 적용할
수 있습니다.
The Alarm Unit DG 3600 is used to monitor limit values and regulate simple automation processes in temperature measuring applications with Pt-Sensors.
High reliability and Protective Separation are essential characteristics that contribute to fault-free equipment operation. Two switch channels can be separately configured. The switch point and the switch hysteresis can each be adjusted by means of their own 12-turn potentiometer located on the unit’s front panel. The switch state is indicated by a yellow LED. The direction of effect and the mode of operation can be switched by means of DIP switch settings. Both switch outputs can be set up as either MIN or MAX alarms. The relay contacts switch high power loads either as N.O. or N.C. contacts. Protective Separation and the 24 V AC/DC power supply make the DG 3600 universally applicable for all measurement and industrial applications, as well as for building automation. Technical Data
InputSensor Input | Pt100 | Pt200 | Pt500 | Pt1000 | (switchable) |
| Sensor current | | Sensor connection | 3-wire connection / 2-wire connection, switchable | Wire resistor | < 10 Ohm per wire | Temperature measuring range | Zero | -100 °C | -50 °C | 0 °C | +50 °C | (switchable) | Span | 100 K | 200 K | 300 K | 400 K | (switchable) |
| Set point range | 0 to 100 % of input range with 12-turn potentiometer, MIN/MAX-Alarm switchable | Hysteresis | 0 to 60 % of final value with 12-turn potentiometer |
OutputDG 3600 (Relay): Contact type Switching cap. AC max. Switching cap. DC max. | 2 SPDT relays, mode of operation switchable 250 V / 6 A 1500 VA 250 V / 0.2 A 115 V / 0.3 A 30 V / 6 A Recommended minimum load 300 mW / 5 V / 5 mA | DG 3680 (Optocoupler): Contact type Switching capability | 2 optocoupler transistor switches, mode of operation switchable 30 V DC, max. 50 mA | Switch state indicator | Yellow LED | Response time | Approx. 20 ms |
General DataSet point error | < 0.2 % full scale | Temperature coefficient 1) | < 150 ppm/K | Test voltage | 4 kV AC, 50 Hz, 1 min., input against power supply against both switching outputs 2.5 kV AC, 50 Hz, 1 min., switching output I against switching output II | Working voltage 2) (Basic Insulation) | 600 V AC/DC for overvoltage category III and pollution degree 2 acc. to EN 50178 between input, power supply and relay outputs. Up to 300 V AC/D between both relay outputs. | Protection against
electrical shock 2) | Protective separation according to EN 50178 by reinforced insulation up to 300 V AC/DC for overvoltage category II and pollution degree 2 between input, power supply and relay outputs. | Power supply | 24 V AC/DC, ± 15 % | AC: 48 to 62 Hz, approx. 2 VA DC approx. 1 W | Ambient temperature | Operation Transport and storage | –20 °C to +60 °C (-4 to +140 °F) –35 °C to +85 °C (-31 to +185 °F) | EMC 3) | EN 61326 -1 | Construction | 22.5 mm (0.89") housing, protection class: IP 20 mounting on 35 mm DIN rail acc. to EN 60715 | Weight | Approx. 100 g |
Block diagram Dimensions
|
Terminal assignments
5,6 | Pt Input |
11 | N/C |
7 | Pt Input |
9,10 | Output I |
8 | Shield (opt) |
12 | N/O |
| |
| |
1,2 | Power Supply ~ |
15 | N/C |
3,4 | Power Supply ~ |
13,14 | Output II |
| |
16 | N/O |
|
Downloads 제품
주문 코드 Product line품목 |
주문번호 |
Temperature Alarm Unit |
DG 3600 |
여기에
표기된 사양들은 예고 없이 변경될 수 있습니다! (Specifications
listed here are subject to change without notice!)
|